fire retardant fabric logo

2653 Warfield Street Ft Worth, TX 76106

Flame Safe FIRE RETARDANT Coatings / Flame Retardants

Hotline: 800-333-9197 8am-5pm (CST) Ph: 817-740-9197

After Hours: 817-658-9197 email: fireprod@aol.com

 DECKING

Dallas, Fort Worth, Houston, Austin,South Dallas, North Dallas, Dallas County, Houston, Corpus Christi, San Antonio, DFW metroplex, Dallas - Fort Worth, Abilene, Amarillo, Odessa, Midland, El Paso

FIRE POLY 75 E


EXTERIOR FIRE RETARDANT
COATING or SPRAY
FOR ALL SPECIES EXTERIOR WOOD
PLYWOOD ● LUMBER ● TIMBER


  CLASSIFIED
FIRE RETARDANT COATING
SURFACE BURNING CHARACTERISTICS OF APPLIED COATING

Surface
Douglas fir
Flame spread
<25
Smoke developed
<150
Number of preliminary coats
None
Rate per coat (ft2/gal)
--
Number of fire retardant coats
3
Rate per coat (ft2/gal)
500
Number of overcoats
None
Rate per coat (ft2/gal)
--
Flash point of liquid coating:
  Fire retarding coating - closed cup, no flash

 

fire retardant logo

FIRE POLY FP75E

TECHNICAL DATA

INTERIOR / EXTERIOR CLASS A RATING

PRODUCT DESCRIPTION:    Aqueous Based Resin

PRODUCT ANALYSIS
Total Solids
46%   PH
2.2 - 2.5
Weight per gallon
11 lbs Flash point
Non-Flammable
Specific gravity
1.33 Color
Water clear at 78°F. - Slight haze at 50°F. or lower
Volatability
Non-Volatile Solvents
Water(Contains no petroleum or derivatives of petroleum)
Anti-Fungus
excellent Resistance Bacterial
Good Resistance
Linear shrinkage
None Moisture Absorption
None
Corrosive
Mildly Toxic
None (when dry)
Insects, rodents,
aspergilli And other types of molds
Excellent resistance Termites
Excellent resistance
Preservative for wood
Good Scrubability
1000 cycles

RECOMMENDED USE: Interior/Exterior Class A Rating (Flame spread less than 25)

FLAME SAFE FIRE POLY75E is a fire retardant coating. It can be used on any type of wood, porous, or non-porous materials, such as:

Yellow pine Redwood Cedar Douglas Fir
Ponderosa Pine Walnut Poplar Bamboo
Cyprus Plywood Teak Thatching
Mahoghany Hardwoods Softwoods Koa

ENVIRONMENTAL REGULATION:

This product complies will U. S. Federal Regulations concerning the use of lead in paint and hydrocarbon emissions.


QUICK REFERENCE FOR APPLYING FIRE POLY FP 75E

MATERIAL
APPLICATION
COVERAGE
Exterior/Interior wood
any type of wood

Treat before, during or after construction.

Be sure surface is clean and dry before treating.

Apply with sprayer head held at 8 to 12 inches from surface

Apply with brush or roller.

May be necessary to wipe on hardwood surfaces

Treat all surface areas where possible

Do not expose treated area to moisture for 24 hours.

Apply three (3) coats at 600 sq. ft. per gallon with the final coverage rate of 200 sq. ft. per gallon

EXTERIOR / INTERIOR WOODS

           All surfaces to be treated must be clean and dry. Fire Poly 75 E fire retardant coating is water-based, clear liquid that becomes insoluble when dry. Fire Poly 75 E also acts as a preservative, and water proofing agent ultra violet inhibibor, mold and mildew protector and repels insects.. If over coating is intended, Fire Poly 75 E is an excellent surface primer for use under latex paints or can be use as a finished coat overwater based stains.

DO NOT DILUTE OR MIX FIRE POLY FP75E FIRE RETARDANT COATING WITH ANY OTHER PRODUCTS.

         It should be noted that unlike some products, materials treated with Fire Poly 75 E fire retarant coating require no special cutting tools or special fasteners. Contact parts of any equipment should be stainless steel or plastic to prevent chemical reaction and breakdown. Storage may be done in polyethylene containers.

          Ideal for marine use.

 

CAUTION:

          Product must not freeze. It must not be thinned or diluted

OVERSPRAY:

        The overspray will not harm plants or animals. Spills can be flushed with water. A rag wetted with   bleach and water mix will clean up spotting.

CLEAN UP PROCEDURE:

          Airless Equipment.

1. Run clear water through the system until coating is flushed out. When minor sudsing on surface stops, the system is flushed.

2. Run bleach and water mix (1 part to 4 parts) through system as solvent for cleaning any residue.

            3. Repeat Step 1 if any foaming occurs in Step 2.

            4. Lubricate system as specified by equipment manufacturer to combat rusting.

If two or more applications are planned in the same day, the sprayer can be kept clean by running water through the system between applications.

          Brushes/Rollers.

              1. Clean immediately after use.

              2. Wash thoroughly with bleach and water mix (1 part to 4 parts).

SAFETY FIRST

Use approved safety devices (ropes, belts, ridge hooks, ladder, etc.) When working on steep or high areas. Take EXTREME CARE not to step on wet treated area. Surface may be slick until dry.

It is good practice to wear respirator or mask and protect hands with rubber gloves when spraying any coating or chemical. When engineered air control is not feasible, use properly maintained and properly fitted NIOSH approved respirator for solvent vapors. A dusk mask does not provide protection against vapors.

If eye contact occurs, flood with water for fifteen (15) minutes and call a physician. KEEP OUT OF REACH OF CHILDREN. DO NOT TAKE INTERNALLY.

Marine

Marine

Exterior Historical Restoration

Historical Restorartion

Call for pricing and ordering 1-800-333-9197

HOME | CONTACTS | FIRE RETARDANT WOOD | Fire Poly FP75E MSDS | TESTING